Accelerometers

А-15

Accelerometers А-15

Accelerometers A-15 are designed for measurement of linear accelerations in inertial navigation systems, AHRS and control systems of aerial, naval and land vehicles.

Accelerometers are sensors with sensing element made of monocrystal silicon and built-in feed-back electronics. The input signal is analogous.

Подробнее

Performance:

— Parameters are provided at +75±2°C.

Specifications

Input Range, g 25
Scale factor, mA/g 1.0-1.3
— Repeatability, ppm < 200
— Temperature sensitivity, ppm/°С < 200
Bias, mg < 12
— Repeatability, mg < 300
— Temperature sensitivity, mg/°С < 30
Axis Misalignment, mrad < 6
— Repeatability, mg < 100
Zero Drift, g/h < 5 х 10-5
Shock: Amplitude, g  50
Ambient Temperature, °С -60...+80
Operating Temperature, °С -60...+80
Input Voltage [VDC], V ±15
Overall Dimensions, mm 24 х 24 х 21
Weight (including electronics), g < 45
A-16

Accelerometers А-16

Accelerometers A-16 are designed for measurement of linear accelerations in inertial navigation systems, AHRS and control systems of aerial, naval and land vehicles.

Accelerometers are sensors with sensing element made of monocrystal silicon and built-in feed-back electronics. The input signal is analogous.

Подробнее

Performance:

— Parameters are provided at +75±2°C.

Specifications

Input Range, g 35
Scale factor, mA/g 0,8-1,2
— Repeatability, ppm <200
— Temperature sensitivity, ppm/°С <200
Bias, mg <17
— Repeatability, mg <300
— Temperature sensitivity, mg/°С <30
Axis Misalignment, mrad <8
— Repeatability, mg <100
Zero drift, g/h <7х10-5
Shock: amplitude, g  50
Ambient temperature, °С -60...+80
Operating temperature, °С -60...+75
Input Voltage [VDC], V ±15
Overall Dimensions, mm 24х24х21
Weight (including electronics), g <45
А-17

Accelerometers А-17

Accelerometers A-17 are designed for measurement of linear accelerations in inertial navigation systems, AHRS and control systems of aerial, naval and land vehicles.

Accelerometers are sensors with sensing element made of monocrystal silicon and built-in feed-back electronics. The input signal is analogous.

Подробнее

Performance:

— Accelerometers A-17 are used in temperature-stabilized devices.

— Parameters are provided at +75±2°C.

Specifications

Input Range, g 10
Scale factor, mA/g 1,0-1,4
— Repeatability, ppm <200
— Temperature sensitivity, ppm/°С <200
Bias, mg <12
— Repeatability, mg <100
— Temperature sensitivity, mg/°С <20
Axis Misalignment, mrad <9
— Repeatability, mg <100
Zero drift, g/h <2,5х10-5
Shock: amplitude, g  30
Ambient temperature, °С -60...+80
Operating temperature, °С +75±2°С
Input Voltage [VDC], V ±15
Overall Dimensions, mm 24х24х21
Weight (including electronics), g <45
A-18

Accelerometers А-18

Accelerometers A-18 are designed for measurement of linear accelerations in inertial navigation systems, AHRS and control systems of aerial, naval and land vehicles.

Accelerometers are sensors with sensing element made of monocrystal silicon and built-in feed-back electronics. The input signal is analogous.

Подробнее

Performance:

— Parameters are provided at +75±2°C.

Specifications

Input Range, g -25*
Scale factor, mA/g 0,5-1,1
— Repeatability, ppm <200
— Temperature sensitivity, ppm/°С <200
Bias, mg <29
— Repeatability, mg <300
— Temperature sensitivity, mg/°С <30
Axis Misalignment, mrad <9
— Repeatability, mg <100
Zero drift, g/h <7х10-5
Shock: amplitude, g  150
Ambient temperature, °С -60...+80
Operating temperature, °С -60...+80
Input Voltage [VDC], V ±15
Overall Dimensions, mm 24х24х21
Weight (including electronics), g <45
* - measurement range extention is allowed by agreement
A-18T

Accelerometers А-18T

Accelerometers A-18T are designed for measurement of linear accelerations in inertial navigation systems, AHRS and control systems of aerial, naval and land vehicles. A-18T is modification of A-18 with improved technical and operational characteristics.

Accelerometers are sensors with sensing element made of monocrystal silicon and built-in feed-back electronics. The input signal is analogous.

Подробнее

Performance:

— Parameters are provided at +75±2°C.

Specifications

Input Range, g -35*
Scale factor, mA/g 0,8-1,2
— Repeatability, ppm <50
— Temperature sensitivity, ppm/°С 120
Bias, mg <18
— Repeatability, μg 50
— Temperature sensitivity, μg/°С <20
Axis Misalignment, mrad <6
— Repeatability, μg 25
Zero drift, g/h <7х10-5
Shock: amplitude, g  100
Ambient temperature, °С -60...+80
Operating temperature, °С -60...+80
Input Voltage [VDC], V ±15
Overall Dimensions, mm 38x38x22.2
Weight (including electronics), g <55
* - measurement range extention is allowed by agreement